Catalog No.
KDD17203
Description
PRINCIPLE OF THE ASSAY This assay employs the quantitative competitive enzyme immunoassay technique. Recombinant Human CD152 has been pre-coated onto a microplate. Standards or samples are premixed with biotin-labeled antibody and then pipetted into the wells. Zalifrelimab in the sample competitively binds to the pre-coated protein with biotin-labeled Zalifrelimab. After washing away any unbound substances, Streptavidin-HRP is added to the wells. Following a wash to remove any unbound enzyme reagent, a substrate solution is added to the wells and color develops in inversely proportion to the amount of Zalifrelimab bound in the initial step. The color development is stopped and the intensity of the color is measured.
Applications
Used for the quantitative determination of Zalifrelimab concentration in serum and plasma.
Detection method
Colorimetric
Sample type
Plasma, Serum
Assay type
Quantitative
Range
78.13 - 5,000 ng/mL
Sensitivity
39.15 ng/mL
Precision
Intra-Assay Precision (Precision within an assay): <20%
Three samples of known concentration were tested sixteen times on one plate to assess intra-assay precision.
Inter-Assay Precision (Precision between assays): <20%
Three samples of known concentration were tested in twenty four separate assays to assess inter-assay precision.
|
Intra-Assay Precision |
Inter-Assay Precision |
||||
Sample |
1 |
2 |
3 |
1 |
2 |
3 |
n |
16 |
16 |
16 |
24 |
24 |
24 |
Mean (ng/mL) |
3257.4 |
615.9 |
130.2 |
2609.2 |
689.2 |
106.7 |
Standard deviation |
375.4 |
65.4 |
23.3 |
358.7 |
94.8 |
20.7 |
CV (%) |
11.5 |
10.6 |
17.9 |
13.7 |
13.7 |
19.4 |
Recovery
80-120%
Shipping
2-8 ℃
Stability and Storage
When the kit was stored at the recommended temperature for 6 months, the signal intensity decreased by less than 20%.
Alternative Names
AGEN1884, CAS: 2148321-69-9
Background
Zalifrelimab is a novel, fully human monoclonal immunoglobulin G1 (IgG1) designed to block CTLA-4 (cytotoxic T-lymphocyte associated antigen 4) from interacting with its ligands CD80 and CD86. CTLA-4 is a negative regulator of immune activation that is considered a foundational target within the immuno-oncology market.